Order by:
RecommendBestsellersLow-pricedHigh-pricedQuantity
|
9 days, 4314 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: No
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 400
Control triggering current, mA: 30
Holding current, mA: 0.1
Operating temperature, ° C: -40…+85
Housing: DIP-6(300 mil)
|
quick view |
9 days, 4314 pcs. |
105 ֏ × |
from 100 pcs. — 96 ֏
|
|
9 days, 3384 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: No
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 400
Control triggering current, mA: 30
Holding current, mA: 0.1
Operating temperature, ° C: -40…+85
Housing: SOP-6
|
quick view |
9 days, 3384 pcs. |
96 ֏ × |
from 100 pcs. — 82 ֏
|
|
9 days, 3157 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: No
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 400
Control triggering current, mA: 15
Holding current, mA: 0.1
Operating temperature, ° C: -40…+85
Housing: DIP-6(300 mil)
|
quick view |
9 days, 3157 pcs. |
91 ֏ × |
from 100 pcs. — 77 ֏
|
|
9 days, 1029 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: No
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 400
Control triggering current, mA: 15
Holding current, mA: 0.1
Operating temperature, ° C: -40…+85
Housing: SOP-6
|
quick view |
9 days, 1029 pcs. |
98 ֏ × |
from 100 pcs. — 86 ֏
|
|
9 days, 1446 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: No
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 400
Control triggering current, mA: 10
Holding current, mA: 0.1
Operating temperature, ° C: -40…+85
Housing: DIP-6(300 mil)
|
quick view |
9 days, 1446 pcs. |
91 ֏ × |
from 100 pcs. — 77 ֏
|
|
9 days, 845 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: No
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 400
Control triggering current, mA: 10
Holding current, mA: 0.1
Operating temperature, ° C: -40…+85
Housing: SOP-6
|
quick view |
9 days, 845 pcs. |
98 ֏ × |
from 100 pcs. — 86 ֏
|
|
9 days, 1999 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: No
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 400
Control triggering current, mA: 5
Holding current, mA: 0.1
Operating temperature, ° C: -40…+85
Housing: DIP-6(300 mil)
|
quick view |
9 days, 1999 pcs. |
93 ֏ × |
from 100 pcs. — 82 ֏
|
|
9 days, 2094 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: No
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 400
Control triggering current, mA: 5
Holding current, mA: 0.1
Operating temperature, ° C: -40…+85
Housing: SOP-6
|
quick view |
9 days, 2094 pcs. |
93 ֏ × |
from 100 pcs. — 82 ֏
|
|
9 days, 949 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: There are
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 400
Critical rate of rise of voltage in the off-state dV / dt, V / us: 1000
Control triggering current, mA: 15
Holding current, mA: 0.4
Operating temperature, ° C: -40…+85
Housing: DIP-6(300 mil)
|
quick view |
9 days, 949 pcs. |
105 ֏ × |
from 100 pcs. — 91 ֏
|
|
9 days, 1668 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: There are
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 400
Critical rate of rise of voltage in the off-state dV / dt, V / us: 1000
Control triggering current, mA: 10
Holding current, mA: 0.4
Operating temperature, ° C: -40…+85
Housing: DIP-6(300 mil)
|
quick view |
9 days, 1668 pcs. |
101 ֏ × |
from 100 pcs. — 86 ֏
|
|
9 days, 2471 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: There are
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 400
Critical rate of rise of voltage in the off-state dV / dt, V / us: 1000
Control triggering current, mA: 5
Holding current, mA: 0.4
Operating temperature, ° C: -40…+85
Housing: DIP-6(300 mil)
|
quick view |
9 days, 2471 pcs. |
101 ֏ × |
from 100 pcs. — 86 ֏
|
|
9 days, 1944 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: There are
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 400
Critical rate of rise of voltage in the off-state dV / dt, V / us: 1000
Control triggering current, mA: 5
Holding current, mA: 0.4
Operating temperature, ° C: -40…+85
Housing: SOP-6
|
quick view |
9 days, 1944 pcs. |
96 ֏ × |
from 100 pcs. — 86 ֏
|
|
9 days, 684 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: No
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 600
Critical rate of rise of voltage in the off-state dV / dt, V / us: 1000
Control triggering current, mA: 15
Holding current, mA: 0.22
Operating temperature, ° C: -40…+85
Housing: DIP-6(300 mil)
|
quick view |
9 days, 684 pcs. |
101 ֏ × |
from 100 pcs. — 86 ֏
|
|
9 days, 2749 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: No
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 600
Critical rate of rise of voltage in the off-state dV / dt, V / us: 1000
Control triggering current, mA: 15
Holding current, mA: 0.22
Operating temperature, ° C: -40…+85
Housing: DIP-6(300 mil)
|
quick view |
9 days, 2749 pcs. |
110 ֏ × |
from 100 pcs. — 96 ֏
|
|
9 days, 1648 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: No
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 600
Critical rate of rise of voltage in the off-state dV / dt, V / us: 1000
Control triggering current, mA: 15
Holding current, mA: 0.22
Operating temperature, ° C: -40…+85
Housing: SOP-6
|
quick view |
9 days, 1648 pcs. |
134 ֏ × |
from 100 pcs. — 115 ֏
|
|
9 days, 1225 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: No
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 600
Critical rate of rise of voltage in the off-state dV / dt, V / us: 1000
Control triggering current, mA: 6
Holding current, mA: 0.54
Operating temperature, ° C: -40…+85
Housing: DIP-6(300 mil)
|
quick view |
9 days, 1225 pcs. |
101 ֏ × |
from 100 pcs. — 86 ֏
|
quick view |
9 days, 319 pcs. |
108 ֏ × |
from 100 pcs. — 101 ֏
|
|
|
9 days, 2874 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: There are
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 600
Critical rate of rise of voltage in the off-state dV / dt, V / us: 600
Control triggering current, mA: 15
Holding current, mA: 0.5
Operating temperature, ° C: -40…+85
Housing: DIP-6(300 mil)
|
quick view |
9 days, 2874 pcs. |
155 ֏ × |
from 100 pcs. — 143 ֏
|
|
9 days, 3049 pcs.
Brand: UMW
Output type: Triac
Zero crossing detector: There are
Number of channels: 1
Isolation voltage (RMS), V: 4170
Maximum off-state voltage, V: 600
Critical rate of rise of voltage in the off-state dV / dt, V / us: 600
Control triggering current, mA: 10
Holding current, mA: 0.5
Operating temperature, ° C: -40…+85
Housing: DIP-6(300 mil)
|
quick view |
9 days, 3049 pcs. |
105 ֏ × |
from 100 pcs. — 91 ֏
|
|
9 days, 560 pcs.
Brand: UMW
|
quick view |
9 days, 560 pcs. |
117 ֏ × |
from 50 pcs. — 110 ֏
|
Page
- 1
- 2
Products by page
- 20
- 40
- 60