DT-9935, Professional LCR (RLC) Meter with automatic measurement mode selection
Images are for reference only,
see technical documentation
see technical documentation
SKU
9000228525
Brand
Resistance measurement
Yes
Capacitance measurement
Yes
Inductance measurement
Yes
Weight, kg
1
All parameters
DT-9935
pdf, 679 КБ
All documents
10 pcs. from the central warehouse, term 9 days
108 000 ֏
from 2 pcs. —
105 000 ֏
1 pcs.
amount of 108 000 ֏
Description
Reviews
DT-9935 is a professional LCR meter with automatic selection of measurement mode - L, C or R. In addition, the device additionally measures the quality factor, damping factor, dielectric loss tangent (Q, D, θ). High accuracy is achieved with a 4-wire measuring circuit.
Peculiarities:
Overload indication
Low battery indication
Auto power off
Protection IEC61000
Dual backlit LCD display
Wiring Diagram: Serial/Parallel
· DATA HOLD
Relative REL measurements
Calibration
Validation with a given tolerance level
Automatic and manual selection of the measuring range
5 testing frequencies
Measurement of resistance to direct and alternating current
Specifications:
Testing frequency: 100Hz, 120Hz, 1KHz, 10KHz, 100KHz
Measurement voltage: 0.6V
· Validation with a given tolerance level: 0.25%, 0.5%, 1%, 2%, 5%, 10%, 20%, +80%…-20%
Inductance: 20kH: ±1.2%
Capacitance: 20mF: ±0.8%
Resistance: 200MOhm: ±0.5%
Quality factor: 0.000-999
Attenuation coefficient: 0.000-999
Loss Tangent: ±90
Dimensions: 220 x 96 x 60 mm
Weight: 360g
Delivery set: case, device, probes, user manual, battery 6 pcs 1.5 V type AA.
Peculiarities:
Overload indication
Low battery indication
Auto power off
Protection IEC61000
Dual backlit LCD display
Wiring Diagram: Serial/Parallel
· DATA HOLD
Relative REL measurements
Calibration
Validation with a given tolerance level
Automatic and manual selection of the measuring range
5 testing frequencies
Measurement of resistance to direct and alternating current
Specifications:
Testing frequency: 100Hz, 120Hz, 1KHz, 10KHz, 100KHz
Measurement voltage: 0.6V
· Validation with a given tolerance level: 0.25%, 0.5%, 1%, 2%, 5%, 10%, 20%, +80%…-20%
Inductance: 20kH: ±1.2%
Capacitance: 20mF: ±0.8%
Resistance: 200MOhm: ±0.5%
Quality factor: 0.000-999
Attenuation coefficient: 0.000-999
Loss Tangent: ±90
Dimensions: 220 x 96 x 60 mm
Weight: 360g
Delivery set: case, device, probes, user manual, battery 6 pcs 1.5 V type AA.
Technical parameters
| Resistance measurement | Yes | |
| Capacitance measurement | Yes | |
| Inductance measurement | Yes | |
| State Register of the Russian Federation | No | |
| Weight, kg | 1 |
Technical documentation
Delivery terms
Delivery to Yerevan
| Office CHIP AND DIP | 2 February1 | free |
| HayPost | 6 February1 | 1 650 ֏2 |
1 estimated delivery date depends on the date of payment or order confirmation
2 for parcels weighing up to 1 kg