ITT40-2-10-0600 , Current transformer TTI-60 600/5A 10VA without busbar accuracy class 0.5
Images are for reference only,
see technical documentation
see technical documentation
34 pcs. from the central warehouse, term 9 days
6 700 ֏
1 pcs.
amount of 6 700 ֏
View analogs1
Products with similar characteristics
Description
Reviews
• PURPOSE
Designed for converting current to a value convenient for measuring, transmitting a signal of measuring information to measuring, protection, automation, signaling and control devices in electrical circuits of alternating current with a frequency of 50 Hz and a rated voltage up to 0.66 kV inclusive.
• APPLICATION AREA
They are used in systems for commercial accounting of energy consumption, in measurement and control circuits with high currents. Allows you to perform galvanic isolation of power and control circuits to improve safety.
• OPERATING PRINCIPLE
When using the TTI-A transformer, the power wire is connected to the terminals of the primary winding of the transformer, when using transformers of the TTI-30 - TTI-125 models, the current-carrying bus is passed through the transformer window and is the primary winding.
A current is taken from the secondary winding, which is to be measured, and the current flowing through the secondary winding of the transformer is proportional to the current flowing in its primary winding and can be determined by calculation.
• OPTIONAL ACCESSORIES OR ACCESSORIES
Each transformer is supplied with a cover that closes the terminals of the secondary winding.
TTI-A transformers are equipped with screws and nuts for fixing conductors. Transformers TTI-30 - TTI-125 are equipped with a bracket for fastening the busbar in the transformer window.
Additional accessories are not required.
Designed for converting current to a value convenient for measuring, transmitting a signal of measuring information to measuring, protection, automation, signaling and control devices in electrical circuits of alternating current with a frequency of 50 Hz and a rated voltage up to 0.66 kV inclusive.
• APPLICATION AREA
They are used in systems for commercial accounting of energy consumption, in measurement and control circuits with high currents. Allows you to perform galvanic isolation of power and control circuits to improve safety.
• OPERATING PRINCIPLE
When using the TTI-A transformer, the power wire is connected to the terminals of the primary winding of the transformer, when using transformers of the TTI-30 - TTI-125 models, the current-carrying bus is passed through the transformer window and is the primary winding.
A current is taken from the secondary winding, which is to be measured, and the current flowing through the secondary winding of the transformer is proportional to the current flowing in its primary winding and can be determined by calculation.
• OPTIONAL ACCESSORIES OR ACCESSORIES
Each transformer is supplied with a cover that closes the terminals of the secondary winding.
TTI-A transformers are equipped with screws and nuts for fixing conductors. Transformers TTI-30 - TTI-125 are equipped with a bracket for fastening the busbar in the transformer window.
Additional accessories are not required.
Technical parameters
| Weight, g | 720 |