Contactor NXC-50 50A 220V/AC3 1NO+1NZ 50Hz (R) CHINT 836788
Images are for reference only,
see technical documentation
see technical documentation
SKU
9001129595
Brand
Number of NO main contacts
3
Type of inrush current
Variable
Modular design
No
Rated Operational Power (NEMA)
22 kW
Weight, kg
1.01
All parameters
Datasheet
pdf, 2574 КБ
All documents
9 pcs. from the central warehouse, term 12 days
28 400 ֏
1 pcs.
amount of 28 400 ֏
Alternative offers2
The same product with different prices and delivery dates
View analogs20
Products with similar characteristics
Description
Reviews
Series
NXC
Number of poles
3
Degree of protection (IP)
IP10
Environmental pollution category
3
Overall and installation dimensions (WxHxD), mm
77x129x118
Rated current, A
50
Control voltage type
Alternating current (AC)
Rated insulation voltage, V
690
The number of main normally open (BUT) contacts
3
Number of main normally closed (NC) contacts
0
Rated switching power, kW
22
Mechanical wear resistance, cycles
9000000
Electrical wear resistance, cycles
1200000
Ambient operating temperature,°C
-35…+70
Rated voltage, V
380...400
Altitude above sea level up to, m
2000
Rated supply voltage of the AC control circuit, V
220
The number of auxiliary normally open (BUT) contacts
1
Number of auxiliary normally closed (NC) contacts
1
Control voltage: retraction, %
70-120
Control voltage: opening, %
20-65
Warranty period for the end user, months from the date of sale
no more than 18
NXC
Number of poles
3
Degree of protection (IP)
IP10
Environmental pollution category
3
Overall and installation dimensions (WxHxD), mm
77x129x118
Rated current, A
50
Control voltage type
Alternating current (AC)
Rated insulation voltage, V
690
The number of main normally open (BUT) contacts
3
Number of main normally closed (NC) contacts
0
Rated switching power, kW
22
Mechanical wear resistance, cycles
9000000
Electrical wear resistance, cycles
1200000
Ambient operating temperature,°C
-35…+70
Rated voltage, V
380...400
Altitude above sea level up to, m
2000
Rated supply voltage of the AC control circuit, V
220
The number of auxiliary normally open (BUT) contacts
1
Number of auxiliary normally closed (NC) contacts
1
Control voltage: retraction, %
70-120
Control voltage: opening, %
20-65
Warranty period for the end user, months from the date of sale
no more than 18
Technical parameters
| Number of auxiliary NO contacts | 1 | |
| Number of NC auxiliary contacts | 1 | |
| Number of NO main contacts | 3 | |
| Rated supply voltage of the control circuit Us var. AC current at 50 Hz | 230V | |
| Rated supply voltage of the control circuit Us var. AC current at 50 Hz with | 220 V | |
| Type of inrush current | Variable | |
| Number of normally open contacts | 0 | |
| Rated supply voltage of the control circuit Us DC DC | 0 V | |
| Rated control supply voltage Us of direct current DC with | 0 V | |
| Modular design | No | |
| Rated Operational Power (NEMA) | 22 kW | |
| Weight, kg | 1.01 |
Technical documentation
Video
Delivery terms
Delivery to Yerevan
| Office CHIP AND DIP | 2 March1 | free |
| HayPost | 6 March1 | 1 650 ֏2 |
1 estimated delivery date depends on the date of payment or order confirmation
2 for parcels weighing up to 1 kg