USB/RS232/RS485/TTL Converter, Isolated USB/RS232/RS485/TTL multi-channel converter

Images are for reference only,
see technical documentation
see technical documentation





99 pcs. from the central warehouse, term 5-7 working days
25 400 ֏
17 100 ֏
from 5 pcs. —
16 300 ֏
Add to Shopping Cart 1 pcs.
amount of 17 100 ֏
Description
Multibus USB/RS232/RS485/TTL converter with integrated power supply isolation, digital isolation and protection circuits.
Peculiarities:
- Convert USB/RS232/TTL to RS232/RS485/TTL;
- Original FT232RL chip, fast communication, stable and reliable;
- Built-in overvoltage and overcurrent protection circuits;
- Power supply isolation, ensure stable isolated voltage;
- Built-in magnetic isolation, ensuring signal isolation, high reliability, strong anti-interference, low power consumption;
- Built-in TVS (transient voltage suppressor), effectively suppresses overvoltage and transient peak voltage in the circuit;
- Built-in self-healing fuse and protection diodes ensure stable current/voltage outputs;
- Built-in TTL 3.3V/5V voltage converter, group B terminal TTL level setting by switch;
- Aluminum alloy body.
Characteristics:
- Baud rate: 300 ~ 921600 bps, 300 ~ 600000 bps (RS232 to RS232);
- Operating temperature: -25℃ ~ 85℃.
- Working humidity: 5%RH ~ 95%RH.
- Supported OS: Windows 11/10/8.1/8/7/XP.
Group A USB:
- Operating voltage: 5 V;
- Connector: USB-B;
- Protection: 200mA resettable fuse, isolated output.
Group A RS232:
- Connector: DB9 plug;
- Protection: TVS protection, surge suppression, ESD protection;
- Transmission mode: point-to-point.
Group A TTL (UART):
- Operating voltage: 5V;
- Connector: screw terminal;
- Pinout: TXD, RXD, GND, 5V;
- Protection: blocking diode, surge protection, anti-reverse protection, anti-jamming.
Group B RS485:
- Connector: screw terminal;
- Pinout: A+, B-, GND;
- Direction control: hardware automatic control;
- Protection: lightning protection, surge protection, electrostatic discharge protection;
- Transmission mode: point-to-multipoints (up to 32 nodes, it is recommended to use repeaters for 16 nodes or more).
Group B RS232:
- Connector: DB9 plug;
- Protection: TVS protection, surge suppression, ESD protection;
- Transmission mode: point-to-point.
Group B TTL (UART):
- Operating voltage: 3.3/5V;
- Connector: screw terminal;
- Pinout: TXD, RXD, GND, 5V;
- Protection: blocking diode, surge protection, anti-reverse protection, anti-jamming.
NOTE: Only one pair of devices will be matched for full communication between Group A and Group B terminals at the same time.
Equipment:
1 x Converter (Multibus Converter);
1 x Cable (USB cable (~1.2m)).
Peculiarities:
- Convert USB/RS232/TTL to RS232/RS485/TTL;
- Original FT232RL chip, fast communication, stable and reliable;
- Built-in overvoltage and overcurrent protection circuits;
- Power supply isolation, ensure stable isolated voltage;
- Built-in magnetic isolation, ensuring signal isolation, high reliability, strong anti-interference, low power consumption;
- Built-in TVS (transient voltage suppressor), effectively suppresses overvoltage and transient peak voltage in the circuit;
- Built-in self-healing fuse and protection diodes ensure stable current/voltage outputs;
- Built-in TTL 3.3V/5V voltage converter, group B terminal TTL level setting by switch;
- Aluminum alloy body.
Characteristics:
- Baud rate: 300 ~ 921600 bps, 300 ~ 600000 bps (RS232 to RS232);
- Operating temperature: -25℃ ~ 85℃.
- Working humidity: 5%RH ~ 95%RH.
- Supported OS: Windows 11/10/8.1/8/7/XP.
Group A USB:
- Operating voltage: 5 V;
- Connector: USB-B;
- Protection: 200mA resettable fuse, isolated output.
Group A RS232:
- Connector: DB9 plug;
- Protection: TVS protection, surge suppression, ESD protection;
- Transmission mode: point-to-point.
Group A TTL (UART):
- Operating voltage: 5V;
- Connector: screw terminal;
- Pinout: TXD, RXD, GND, 5V;
- Protection: blocking diode, surge protection, anti-reverse protection, anti-jamming.
Group B RS485:
- Connector: screw terminal;
- Pinout: A+, B-, GND;
- Direction control: hardware automatic control;
- Protection: lightning protection, surge protection, electrostatic discharge protection;
- Transmission mode: point-to-multipoints (up to 32 nodes, it is recommended to use repeaters for 16 nodes or more).
Group B RS232:
- Connector: DB9 plug;
- Protection: TVS protection, surge suppression, ESD protection;
- Transmission mode: point-to-point.
Group B TTL (UART):
- Operating voltage: 3.3/5V;
- Connector: screw terminal;
- Pinout: TXD, RXD, GND, 5V;
- Protection: blocking diode, surge protection, anti-reverse protection, anti-jamming.
NOTE: Only one pair of devices will be matched for full communication between Group A and Group B terminals at the same time.
Equipment:
1 x Converter (Multibus Converter);
1 x Cable (USB cable (~1.2m)).
Technical parameters
Converter type | usb/rs-232/ttl to rs-232/rs-485/ttl | |
Number of ports | 1 | |
Body material | metal | |
Mounting type | installation on a flat surface | |
Connector type | usb/rs-232(db9m)/rs-485/ttl(terminals) | |
Galvanic isolation | There are | |
Protection against impulse noise | There are | |
Weight, g | 282 | |
Technical documentation
Multibus Converter
pdf, 288 КБ
Delivery terms
Delivery to Yerevan
Office CHIP AND DIP | 2 October1 | free |
HayPost | 5 October1 | 1 650 ֏2 |
1 estimated delivery date depends on the date of payment or order confirmation
2 for parcels weighing up to 1 kg