TDGC2-3 3KVA 12A 250V, 1-phase autotransformer (LATR)

see technical documentation
Description
TDGC2 single-phase dry autotransformer with stepless regulation of AC voltage with a frequency of 50-60Hz from 0 to 250V under load without breaking the circuit. Rated load currents are 12A.
A voltmeter is built into the body of the autotransformers.
TDGC2 series autotransformers are widely used in various electrical engineering works, in scientific laboratories, as well as for powering various household appliances and tools.
Technical specifications
The TDGC2-3K model
Power - 3 kVA
Rated current - 12 A
Number of phases 1
Frequency - 50 Hz
The input voltage is 220 V
Output voltage - 0-250 V
Overall dimensions 220x205x190 mm
Weight - 11 kg
TDGC2 autotransformers must be operated in an explosion-proof environment free of dust, as well as aggressive gases and vapors in concentrations that destroy metals and insulation.
TDGC2 autotransformers are devices that are unstable to short circuits, so the consumer must connect them to a network that is protected by fuses with a current equal to the rated current of the transformer or by another type of protective device, such as a circuit breaker.
The autotransformers must be grounded during operation.
Continuous operation under load - no more than 8 hours.
The ambient temperature ranges from minus 40 to plus 60 C.