DT-9935, Professional LCR(RLC) meter with automatic measurement mode selection

Images are for reference only,
see technical documentation
see technical documentation



16 pcs. from the central warehouse, term 7 days
97 900 ֏
from 2 pcs. —
95 600 ֏
1 pcs.
amount of 97 900 ֏
Description
DT-9935 is a professional LCR meter with automatic selection of measurement mode - L, C or R. In addition, the device additionally measures the quality factor, damping factor, dielectric loss tangent (Q, D, θ). High accuracy is achieved with a 4-wire measuring circuit.
Peculiarities:
Overload indication
Low battery indication
Auto power off
Protection IEC61000
Dual backlit LCD display
Wiring Diagram: Serial/Parallel
· DATA HOLD
Relative REL measurements
Calibration
Validation with a given tolerance level
Automatic and manual selection of the measuring range
5 testing frequencies
Measurement of resistance to direct and alternating current
Specifications:
Testing frequency: 100Hz, 120Hz, 1KHz, 10KHz, 100KHz
Measurement voltage: 0.6V
· Validation with a given tolerance level: 0.25%, 0.5%, 1%, 2%, 5%, 10%, 20%, +80%…-20%
Inductance: 20kH: ±1.2%
Capacitance: 20mF: ±0.8%
Resistance: 200MOhm: ±0.5%
Quality factor: 0.000-999
Attenuation coefficient: 0.000-999
Loss Tangent: ±90
Dimensions: 220 x 96 x 60 mm
Weight: 360g
Delivery set: case, device, probes, user manual, battery 6 pcs 1.5 V type AA.
Peculiarities:
Overload indication
Low battery indication
Auto power off
Protection IEC61000
Dual backlit LCD display
Wiring Diagram: Serial/Parallel
· DATA HOLD
Relative REL measurements
Calibration
Validation with a given tolerance level
Automatic and manual selection of the measuring range
5 testing frequencies
Measurement of resistance to direct and alternating current
Specifications:
Testing frequency: 100Hz, 120Hz, 1KHz, 10KHz, 100KHz
Measurement voltage: 0.6V
· Validation with a given tolerance level: 0.25%, 0.5%, 1%, 2%, 5%, 10%, 20%, +80%…-20%
Inductance: 20kH: ±1.2%
Capacitance: 20mF: ±0.8%
Resistance: 200MOhm: ±0.5%
Quality factor: 0.000-999
Attenuation coefficient: 0.000-999
Loss Tangent: ±90
Dimensions: 220 x 96 x 60 mm
Weight: 360g
Delivery set: case, device, probes, user manual, battery 6 pcs 1.5 V type AA.
Technical parameters
Resistance measurement | Yes | |
Capacitance measurement | Yes | |
Inductance measurement | Yes | |
State Register of the Russian Federation | нет | |
Weight, kg | 1 |
Technical documentation
Delivery terms
Delivery to Yerevan
Office CHIP AND DIP | 24 March1 | free |
HayPost | 28 March1 | 1 650 ֏2 |
1 estimated delivery date depends on the date of payment or order confirmation
2 for parcels weighing up to 1 kg